TCU - friendly and intelligent.
With the TCU controller, you can adjust your Teddington air curtain system exactly to the most varied demands. On the LCD-Display, you have all the functions and parameters clearly visible. The programming of the varied functions and options is thus extremely simple and intuitively feasible. Over an integrated BUS-System, up to 9 air curtain systems can be regulated with only one control bezel. The handling of complex and formidable systems is simplified. |
 |
Teddington controller unit TC5
5-stage electronic air volume controller with LCD Display
for setting and indication of the operating status.
Manual / Automatic mode via potential-free contact with
adjustable after-run time. Summer / Winter function.
Filter maintenance function with signalling at the control
panel, indication and analysis of the fan failure error
signal, transformer failure via the thermal contacts
and danger of frost via the optional frost protection
thermostat. The integrated frost protection circuit
deactivates the ventilators whenever there is the danger
of frost and releases the valve or pump. A repair switch for
switching off the unit by software is available. For GLT
coupling, an external release and an operating and fault
message are all made available. The connection of the
control panel and up to 9 slave units takes place via a
simple 2-core bus cable. The terminals are reverse
connection and short circuit protected. The controller has
got an integrated key lock function as well as an operating
hours counter.
Dimensions: 103 x 103 x 29 mm.
|
|
 |
Teddington controller unit TC3
3-stage electronic air volume controller with LCD Display for setting and indication of the operating status. Manual / Automatic mode via potential-free contact and Summer / Winter function. Indication and analysis of the fan failure error signal, transformer failure via the thermal contacts and danger of frost via the optional frost protection thermostat. The integrated frost protection circuit deactivates the ventilators whenever there is the danger of frost and releases the valve or pump. The connection of the control panel and up to 9 slave units takes place via a simple 2-core bus cable. The terminals are reverse connection and short circuit protected. The controller has got an integrated key lock function as well as an operating hours counter.
Dimensions: 103 x 103 x 29 mm. |
 |
DDC 5 (Hot water devices)
5-stage controller pc-board with auxiliary functions, which allows the connection to the building management technology / DDC. All logical combinations as well as operating and failure messages are generated here and be made available via potential free inputs/outputs. Summer-/winter toggle switch; connection of e.g. DDC, door contact, timer, room thermostat; full motor protection; option: Frost protection and repair switch.
Dimensions: 240 x 110 x 55 mm. |
 |
Teddington controller unit TC3E
3-stage electronic air volume controller for electricallyheated air curtain devices, with LCD Display for setting and indication of the operating status. Air volume and heat output are always 3-stage adjustable. The heat output is interlocked with the air volume stage. Manual / Automatic mode via potential-free contact. Safety functions: after-run function controlled by a 50 °C thermostat, overheating protection by a 60 °C thermostat and an additional overheating protection by a 175 °C thermostat. The connection of the control panel and up to 9 slave units takes place via a simple 2-core bus cable. The terminals are reverse connection and short circuit protected. The controller has got an integrated key lock function as well as an operating hours counter.
Dimensions: 103 x 103 x 29 mm. |
 |
ST 3G (hot water device)
3-stage switching device with removable bezel for optional summer / winter or manual / automatic mode.
Measurements: 100 x 79 x 112 mm. |
 |
ST 5G (hot water device)
5-stage switching device with removable bezel for optional summer / winter or manual / automatic mode.
Measurements: 100 x 79 x 112 mm. |
|